CPBEN=DISABLED, HCVCBMD=LOW, CPACEN=DISABLED, HCVCFOEN=DISABLED, BIASSEN=DISABLED, VBMLPEN=DISABLED, FBIASCEN=DISABLED, CMPBLPEN=DISABLED, CPOLPEN=DISABLED, DCDCBIASEN=DISABLED, HCVCBYPEN=DISABLED, MCDEN=DISABLED, CPSMD=EXTERNAL, HCVCHMD=LOW, DCDCSTDBYEN=DISABLED, LCDEN=DISABLED, HCVLPMEN=DISABLED, RBGSEN=DISABLED, RTCCEN=DISABLED, CPFPDEN=DISABLED, BIASEN=DISABLED
Configuration
| LCDEN | Module Enable. 0 (DISABLED): Disable the LCD module. 1 (ENABLED): Enable the LCD module. | 
| CPFPDEN | Charge Pump Full Power Drive Mode Enable. 0 (DISABLED): Disable the LCD charge pump’s full power drive mode. The charge pump draws less power but operates with reduced output current capabilities. 1 (ENABLED): Enable the LCD charge pump’s full output drive mode. The charge pump operates at full power. | 
| MCDEN | LCD Missing Clock Detector Enable. 0 (DISABLED): Disable the dedicated LCD missing clock detector. 1 (ENABLED): Enable the dedicated LCD missing clock detector. | 
| RTCCEN | RTC Clock Request Enable. 0 (DISABLED): The LCD module does not require the RTC clock. 1 (ENABLED): The LCD module requires an active and valid RTC clock (RTC0TCLK). | 
| BIASEN | Bias Enable. 0 (DISABLED): Disable the LCD bias current. 1 (ENABLED): Enable the LCD bias current. | 
| DCDCBIASEN | DCDC Bias Output Enable. 0 (DISABLED): Disable the secondary bias current output. 1 (ENABLED): Enable the secondary bias current output. | 
| DCDCSTDBYEN | DCDC Bias Standy Enable. 0 (DISABLED): The DCDC bias is enabled in Power Mode 8. 1 (ENABLED): The DCDC bias is disabled in Power Mode 8. | 
| CPBEN | Charge Pump Bypass Enable. 0 (DISABLED): The LCD charge pump generates the VLCD voltage. 1 (ENABLED): Bypass the LCD charge pump and connect VLCD directly to VBAT. | 
| HCVLPMEN | High Contrast Voltage Low-Power Mode Enable. 0 (DISABLED): Disable the high contrast voltage low-power mode. 1 (ENABLED): Enable the high contrast voltage low-power mode. This mode reduces power consumption whenVLCD is higher than VBAT. | 
| VBMLPEN | VBAT Monitor Low Power Enable. 0 (DISABLED): Disable the LCD VBAT Monitor low power mode. 1 (ENABLED): Enable the LCD VBAT Monitor low power mode. | 
| CPOLPEN | Charge Pump Oscillator Low Power Enable. 0 (DISABLED): Disable the charge pump oscillator low power mode. 1 (ENABLED): Enable the charge pump oscillator low power mode. | 
| CMPBLPEN | Comparator Buffer Low Power Enable. 0 (DISABLED): Disable the comparator buffer low power mode. 1 (ENABLED): Enable the comparator buffer low power mode. | 
| BIASSEN | Bias Switching Enable. 0 (DISABLED): Disable bias switching. 1 (ENABLED): Enable bias switching. | 
| RBGSEN | Reference Bandgap Switching Enable. 0 (DISABLED): Disable reference bandgap switching mode. 1 (ENABLED): Disable reference bandgap switching mode. | 
| CPACEN | Charge Pump Auto-Contrast Enable. 0 (DISABLED): VLCD continues to track VBAT when VBAT drops below the programmed VLCD value. 1 (ENABLED): The module automatically enables the charge pump and maintains the VLCD voltage when VBAT drops below the programmed VBAT monitor level. | 
| FBIASCEN | Force Bias Continuous Mode Enable. 0 (DISABLED): The bias operates as configured. 1 (ENABLED): Force the bias to operate in continuous mode. The bias will cleanly transition from its configuration settings to continuous mode. | 
| BIASBGR | Bias to Bandgap Switching Cycle Ratio. | 
| HCVCBYPEN | High Contrast Voltage Comparator Bypass Enable. 0 (DISABLED): Hardware enables the high contrast voltage comparator as needed. 1 (ENABLED): High contrast voltage comparator in bypass mode. | 
| HCVCFOEN | High Contrast Voltage Comparator Force On Enable. 0 (DISABLED): Hardware enables the high contrast voltage comparator as needed. 1 (ENABLED): High contrast voltage comparator force on enabled. | 
| HCVCHMD | High Contrast Voltage Comparator Hysteresis. 0 (LOW): Set the high contrast voltage comparator to low hysteresis mode. 1 (HIGH): Set the high contrast voltage comparator to high hysteresis mode. | 
| HCVCBMD | High Contrast Voltage Comparator Bias. 0 (LOW): Set the high contrast voltage comparator to low bias mode. 1 (HIGH): Set the high contrast voltage comparator to high bias mode. | 
| CPSMD | Charge Pump Supply Mode. 0 (EXTERNAL): Select the external supply for the charge pump. 1 (VLCD): Select VLCD as the supply for the charge pump. |